RSM logo
Laboratory Animals

Home Current issue Browse archive Alerts About the journal Feedback
 
This version was published on 1 October 2009
Lab Anim 2009;43:382-389
doi:10.1258/la.2009.0080124
© 2009 Laboratory Animals Limited

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
la.2009.0080124v1
43/4/382    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Google Scholar
Right arrow Articles by Devonshire, I M
Right arrow Articles by Greenfield, S A
PubMed
Right arrow PubMed Citation
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

Original Articles

Design and evaluation of a low-cost respiratory monitoring device for use with anaesthetized animals

I M Devonshire 1 , M J Preston 1, E J Dommett 2, K L Murphy 3 and S A Greenfield 1

1 Department of Pharmacology, University of Oxford, Mansfield Road, Oxford OX1 3QT, UK; 2 Department of Life Sciences, The Open University, Walton Hall, Milton Keynes MK7 6AA, UK; 3 Oxford University Veterinary Services, University of Oxford, Parks Road, Oxford OX1 3PT, UK

Corresponding author: I M Devonshire. Email: ian.devonshire{at}pharm.ox.ac.uk

This report describes a simple, non-invasive electronic device that employs a compact accelerometer integrated circuit to transduce movements in the chest wall of an anaesthetized animal into an analogue signal that can be used to calculate the rate and relative depth of respiration. The device requires amplification by signal processing hardware/software which are common to most experimental laboratories. We assessed the sensitivity of the device by its ability to detect changes in respiratory patterns produced by modulating the depth of anaesthesia in isoflurane-anaesthetized Wistar rats. It is widely accepted that many anaesthetic agents affect respiratory patterns, especially respiratory rate (RR), which is often used as an important index of anaesthetic depth. Respiratory parameters obtained with the device were compared with concurrently recorded electroencephalographic and cardiac measures. Different concentrations of anaesthetic agent produced four depths of anaesthesia, identified using established electroencephalographic criteria. The accelerometer was attached easily and securely to the location of maximal chest wall movement and produced a strong respiratory signal that was detectable in all four anaesthetic stages. Deepening the anaesthesia produced a gradual decrease in RR, a decrease in dominant spectral frequency of the electroencephalogram (EEG) but no change in the heart rate. There was a significant correlation between RR and the dominant spectral frequency of the EEG, indicating that one useful application of the monitor could be to identify anaesthetic stages. The results demonstrate that respiratory parameters can be recorded using a simply constructed, low-cost device and suggest an application in the monitoring of anaesthetic depth.

Key Words: General anaesthesia • respiratory physiology • electroencephalography • electrocardiography • rat